PUE C32 Weighing Terminal

Radwag – Laboratory and Industrial Weighing Solutions
Selected language English
PUE C32 Weighing Terminal
This image is for reference only.

PUE C32 Weighing Terminal

Product code: WX-008-0141
close
Change the model:
PUE C32 Weighing Terminal
Select all
Show me
Download
Overview
The Housing and the Display
The housing is made of durable ABS plastic. The terminal has been equipped with 5’’ colour display ensuring perfect readability, and 22-key membrane keypad featuring programmable function keys. The terminal offers customized menu, with this all your personal needs can be met which makes operation even more intuitive and simple.
 
Battery as an Optional Power Source
Use of the optional battery enables the PUE C32 terminal to operate even when there is either no or unstable power supply.
 
Communication Interfaces
Standard terminal has been equipped with RS 232, USB-A, USB-B, 4×IN, 4×OUT and Ethernet interfaces which facilitate both cooperation with peripherals such as printer or computer and data exchange using USB drives.
The terminal connects with wireless networks due to a Wireless Connection module, which comes standard.

Data Management
PUE C32 information system is based on 7 databases, each of different maximum record quantity::
  • Products - 15 000
  • Operators - 500
  • Formulations - 500
  • Packaging - 500
  • Customers - 500
  • Labels - 500
  • Universal variables – 100
Databases can be imported and exported via USB flash drives.
 
ALIBI Memory
ALIBI memory provides data safety and allows saving up to 500 thousand weighing records.This guaranties continuous storing of data over a long period of time.
Datasheet
Display

5” graphic colour

 

Device dimensions

206×140×71

 mm

Packaging dimensions

300×250×130

 mm

Net weight

0.7

 kg

Gross weight

0.94

 kg

Protection class

IP 43

 

Housing

ABS plastic

 

Communication interface

2×RS232, USB-A, USB-B, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Power supply

100 – 240 V AC 50/60 Hz

 

Optional power supply

internal rechargeable battery

 

Operation time on batteries

operation time up to 5 h

 

Maximum quantity of verification units

6000 e

 

Minimum volatge per verification unit

0.4 µV

 

Maximum voltage per verification unit

3.25 µV

 

Minimum load cell impedance

50 Ω

 

Maximum load cell impedance

1200 Ω

 

Load cell excitation voltage

5V DC

 

Maximum increase of signal

39 mV

 

Connection of load cells

4 or 6 wires + shield

 

Operating temperature

-10 – +40

 °C

Multiple range

YES

 

Max number of platforms

1

 

CE
2 years warranty
* - optional version
Videos
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Datasheet
Data Sheet Data Sheet
Data Sheet

Show me
Show me
Download
Download

Choose more product:
Show me Show me DownloadDownload
User Manuals
Software Manual - CBCP 02
Software Manual - CBCP 02
Show me
Show me
Download
Download
(1.18 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Show me
Show me
Download
Download
(0.99 MB)
Start up Guide
Start up Guide
Show me
Show me
Download
Download
(3.15 MB)
User Manual - PUE C32
User Manual - PUE C32
Show me
Show me
Download
Download
(1.94 MB)
Conformity Declarations
Conformity-Declaration
Conformity-Declaration
Show me
Show me
Download
Download
(0.12 MB)
Publications and Brochures
PUE C32 Terminal
PUE C32 Terminal
Show me
Show me
Download
Download
(3.16 MB)
Download
Drivers

LabVIEW (3.05 MB)

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessories
R-LAB

Accessories

Additional modules

RES Radwag Extended SI Module3

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩