HY10.3/6.H1.PGC Multifunctional Scale

Radwag – Laboratory and Industrial Weighing Solutions
Selected language English
HY10.3/6.H1.PGC Multifunctional Scale
This image is for reference only.

HY10.3/6.H1.PGC Multifunctional Scale

Product code: WK-311-1004
Change the model (7)
done
Max: 3 / 6kgd: 1 / 2g

 150×200mm
expand_more
Max: 1.5 / 3kgd: 0,5 / 1g

 150×200mm
Max: 3 / 6kgd: 1 / 2g

 250×300mm
Max: 6 / 15kgd: 2 / 5g

 250×300mm
Max: 6 / 15kgd: 2 / 5g

 410×410mm
Max: 15 / 30kgd: 5 / 10g

 410×410mm
Max: 30 / 60kgd: 10 / 20g

 410×410mm
Maximum capacity [Max]: 3 / 6 kg
Readability [d]: 1 / 2 g

close
Change the model:
HY10.1,5/3.H1.PGC Multifunctional Scale
HY10.3/6.H1.PGC Multifunctional Scale
HY10.3/6.H2.PGC Multifunctional Scale
HY10.6/15.H2.PGC Multifunctional Scale
HY10.6/15.H3.PGC Multifunctional Scale
HY10.15/30.H3.PGC Multifunctional Scale
HY10.30/60.H3.PGC Multifunctional Scale
Select all
Show me
Download
Add to compare Advanced search
Overview
 

Scale HY10.H for statistic control

 
Scales HY10.PGC series is equipped with module for control of packed goods. The module is supported by database containing products and operators lists. A control started by the scale is automatically stopped after pre-defined quantity of packages (samples) has been controlled. Number of the packages is fixed by scale program depending on product batch size. Scales features 10,1" colourful, graphic touch screen display and full alphanumeric keyboard aiding scale operation and setting control parameters.
 
 
 
 
 

Control cycle runs according to the following scheme:

  • operator choice,
  • product choice,
  • control start,
  • acquiring weighing records,
  • automatic control end after certain packages number,
  • control report print.
 
Each carried out control is ended with a final report containing all information that is necessary for prepacked products control report. The report is automatically saved in scales memory and at the same time it can be printed by printer connected to the scales.
 

 

The purpose of the scale is the packaged goods control (PGC), so remember that verification (legalization) is necessary.
We recommend ordering a scale with a proper verification (legalization).
 
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datasheet
Maximum capacity [Max]

3 / 6

 kg

Minimum load

20 / 40

 g

Readability [d]

1 / 2

 g

Verification unit [e]

1 / 2

 g

Tare range

-6

 kg

OIML Class

III

 

Display

10.1″ graphic colour touchscreen

 

Cable length

1.5

 m

Weighing pan dimensions

150×200

 mm

Packaging dimensions

350×420×470

 mm

Net weight

7

 kg

Gross weight

10

 kg

Protection class

IP 68 construction, IP 68 (1h max)/69 terminal

 

Communication interface

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital)

 

Optional interfaces

module Wi-Fi® 802.11 b/g/n, module Profibus (DP SLAVE), module RS485, module PROFINET (RJ45), analog output module (4-20mA, 0-20mA, 0-10V) , 12IN / 12OUT (IN – 5-24 VDC, OUT – max 30 VDC, 0.5 ADC)

 

Power supply

100 – 240 V AC 50/60 Hz

 

Operating temperature

-10 – +40

 °C

Relative humidity

10% – 85% RH no condensation

 

CE
2 years warranty
Automatic Scales verification
Packaged Goods Control
Videos
Complete Solutions for Mass Measurement in Pharma Industry
HY10 Advanced weighing terminal
RADWAG Remote Desktop
RADWAG Remote Desktop - Windows 10
Functions
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Transactions

Transactions

Complex weighing mode for registration of weighings that are part of transactions such as sale, purchase and warehouse transfer. You can create a new transaction using the scale. It is possible to pause the transaction or abort it.  The function supports warehouse management in an enterprise.
Documentation
Datasheet
Data Sheet Data Sheet
Data Sheet

Show me
Show me
Download
Download

Choose more product:
Show me Show me DownloadDownload
User Manuals
Software Manual - CBCP 03
Software Manual - CBCP 03
Show me
Show me
Download
Download
(0.23 MB)
User Manual - PUE HY10
User Manual - PUE HY10
Show me
Show me
Download
Download
(2.19 MB)
Start up Guide
Start up Guide
Show me
Show me
Download
Download
(1.38 MB)
User Manual - HY10 multifunctional scales
User Manual - HY10 multifunctional scales
Show me
Show me
Download
Download
(1.88 MB)
 Software Manual - PUE HY10
Software Manual - PUE HY10
Show me
Show me
Download
Download
(7.10 MB)
Software Manual - Radwag-Mass -Node-RED
Software Manual - Radwag-Mass -Node-RED
Show me
Show me
Download
Download
(0.57 MB)
 Software Manual - PROFIBUS communication protocol of PUE HY10
Software Manual - PROFIBUS communication protocol of PUE HY10
Show me
Show me
Download
Download
(0.65 MB)
Quick start
Quick start
Show me
Show me
Download
Download
(2.47 MB)
Software Manual - Appendices 01
Software Manual - Appendices 01
Show me
Show me
Download
Download
(1.81 MB)
User Manual - Connecting External Platform
User Manual - Connecting External Platform
Show me
Show me
Download
Download
(0.99 MB)
 Software Manual - PROFINET communication protocol of PUE HY10
Software Manual - PROFINET communication protocol of PUE HY10
Show me
Show me
Download
Download
(1.82 MB)
Conformity Declarations
Conformity Declaration
Conformity Declaration
Show me
Show me
Download
Download
(0.04 MB)
Publications and Brochures
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Show me
Show me
Download
Download
(1.64 MB)
THBR System 2.0
THBR System 2.0
Show me
Show me
Download
Download
(5.17 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Show me
Show me
Download
Download
(2.23 MB)
PUE HY10 - Weighing Terminal
PUE HY10 - Weighing Terminal
Show me
Show me
Download
Download
(2.55 MB)
Accessories
R-LAB

Accessories

Additional modules

Audit Trail3
Workflow - additional module3
RDA (RADWAG Data Access)3
RES Radwag Extended SI Module3

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩