AP-12.1.5Y Automatic Device for Multichannel Pipette Calibration

Radwag – Laboratory and Industrial Weighing Solutions
Selected language English
Obraz
This image is for reference only.

AP-12.1.5Y Automatic Device for Multichannel Pipette Calibration

Product code: WL-101-0423
Change the model (2)
doneexpand_more
Maximum capacity [Max]: 18 g
Readability [d]: 1 µg

close
Change the model:
AP-12.1.5Y Automatic Device for Multichannel Pipette Calibration
AP-12.5Y Automatic Device for Multichannel Pipette Calibration
Select all
Show me
Download
Add to compare Advanced search
Overview
 

AP-12.1.5Y Automatic Device for Multichannel Pipette Calibration

 
 
 
The AP-12.1.5Y is the first automatic device designed to calibrate single- and multi-channel micropipettes with [d] 1 µg, in accordance with ISO 8655 requirements. Pipette calibration can be performed in the volume range from 0.5 μl a maximum of 12 channels of fixed and variable volume pipettes. 
 
The impressive calibration readability is the result of the co-called separation chamber which stabilizes the measurement path and protects it from excessive air movement. This is a guarantee of high precision measurements.
 

AP-12.1.5Y

guarantees the comfort of work. The ergonomic design of the device makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. When calibrating a multichannel pipette, a pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration.
 
Other factors that affect the ergonomics of work:
  • compact, mobile design
  • clear, intuitive multilingual menu
  • data security
  • transfer of results directly to the customer’s computer application
  • internal procedure report
  • automatic periodic adjustment of the device.
 
After emptying a 12-channel pipette, the AP-12.1.5Y  checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.1.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports.
 
The AP-12.1.5Y monitors the ambient conditions using calibrated sensors: THB S (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment).
 
When purchasing the AP-12.1.5Y, you get:
  • two calibrated sensors: THB S and THB W,
  • two weighing pans: standard, and for balance test and calibration,
  • a pump equipped with two nozzles: to draw water from one container or from four containers at once,
  • a brush,
  • a pincette,
  • a vessel for the liquid,
  • the Calibration Certificate for the balance.
Datasheet
Maximum capacity [Max]

18

 g

Readability [d]

1

 µg

Tare range

-18

 g

Standard repeatability [5% Max]

2.8

 µg

Standard repeatability [Max]

3 µg for a single-channel balance
4 µg for a multichannel balance

 

Standard minimum weight (USP)

2

 mg

Standard minimum weight (U=1%, k=2)

0.2

 mg

Linearity

±0.01

 mg

Stabilization time

max 10

 s

Adjustment

internal (automatic)

 

Typical measurement time for a 12-channel pipette with constant volume,
according to ISO 8655 (for d=10 µg)*

under 20 minutes

 

Typical measurement time for a 12-channel pipette with variable volume,
according to ISO 8655 (for d=10µg)*

under 60 minutes

 

Maximum volume

4.5

 ml

Display

10″ graphic colour touchscreen

 

Weighing pan dimensions

ø26 + automat

 

Packaging dimensions

605×560×775

 mm

Net weight

17

 kg

Gross weight

23

 kg

Communication interface

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Operating temperature

+10 – +40

 °C

Operating temperature change rate

±0.3 °C / 1 h (±1 °C / 8 h)

 

Relative humidity

20% – 80%

 

Relative humidity change rate

±1% / h (±4% / 8 h)

 

CE
*Depends on room conditions and user competence.
360°
Videos
New Menu Language in 5Y Series Balances: Japanese
AP-12 Automatic Calibration of Multichannel Pipettes in Your Hands
AP-12.5Y – Speed, Process Automation, Cost Reduction
ELLIPSIS – New Balance by RADWAG
ELLIPSIS – Cutting Edge, Innovative, New
Talk to it. Voice Commands in New ELLIPSIS Balance by RADWAG
310 ELLIPSIS – Scan or Tap to Log In
Remote VPN Support on ELLIPSIS Balances
ELLIPSIS – Unlimited Connections
AP-12.5Y Quick and Easy Single-Channel Pipettes Calibration (Tutorial)
AP-12.5Y Quick and Easy Multi-Channel Pipettes Calibration (Tutorial)
AP-12.5Y Quick and Easy Checking and Calibrating (Tutorial)
Functions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Datasheet
Data Sheet Data Sheet
Data Sheet

Show me
Show me
Download
Download

Choose more product:
Show me Show me DownloadDownload
User Manuals
User manual Web Editor
User manual Web Editor
Show me
Show me
Download
Download
(1.60 MB)
User Manual
User Manual
Show me
Show me
Download
Download
(1.16 MB)
Start up Guide
Start up Guide
Show me
Show me
Download
Download
(3.34 MB)
User Manual
User Manual
Show me
Show me
Download
Download
(2.36 MB)
User Manual
User Manual
Show me
Show me
Download
Download
(1.24 MB)
Software Manual
Software Manual
Show me
Show me
Download
Download
(1.23 MB)
Conformity Declarations
Conformity Declaration
Conformity Declaration
Show me
Show me
Download
Download
(0.04 MB)
Publications and Brochures
AP-12.5Y Automatic Device for Multichannel Pipette Calibration
AP-12.5Y Automatic Device for Multichannel Pipette Calibration
Show me
Show me
Download
Download
(3.26 MB)
RFID
RFID
Show me
Show me
Download
Download
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Show me
Show me
Download
Download
(1.86 MB)
Laboratory Balances
Laboratory Balances
Show me
Show me
Download
Download
(1.68 MB)
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Show me
Show me
Download
Download
(5.49 MB)
Weighing systems for calibration  and verification of piston pipettes
Weighing systems for calibration and verification of piston pipettes
Show me
Show me
Download
Download
(5.27 MB)
Accessories
R-LAB

Accessories

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩
close