HX5.EX is an indicator intended for industry. It represents the newest RADWAG-manufactured equipment designed to be used in areas endangered with explosive atmosphere. HX5.EX is compliant with ATEX directive. The indicator is a device intended to be used in environment filled with explosive gases and dust, it can be operated in zones: 1/21 and 2/22.

Indicator Models 
There are 4 different models:
  • PUE HX5.EX-1: 2 × RS232, RS485 - standard design,
  • PUE HX5.EX-2: standard design + 4I/4O,
  • PUE HX5.EX-3: standard design + 4I,
  • PUE HX5.EX-4: standard design + 4O.
Housing
The housing is made of AISI 304 stainless steel of high protection class: IP66 / IP68 (up to 1.5 m immersion). The indicator features 5" colour LCD display covered with polycarbonate that protects it against shocks, and membrane keyboard. Ease of operation, clear menu and intuitive information arrangement on the display guarantee comfort of operation. Hermetic intrinsically safe interfaces connectors are located on the back side of the housing. Stable mount bracket enables mounting the indicator either on any flat horizontal surface or on the wall where its inclination angle can be easily adjusted.

Power Supply
The PUE HX5.EX indicator can be connected to the mains only with a certified intrinsically safe power supply, manufactured by RADWAG:
  • PM01.EX-1 power supply intended for operation in hazardous area:
    • zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
    • zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2 power supply intended for operation in safe area, equipped with intrinsically safe circuits which may be placed in:
    • zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
    • zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
IM01.EX Communication Module

The interfaces range can be expanded using communication module, connected to a terminal via intrinsically safe IM01.EX, placed outside hazardous area.
Models:
  • IM01.EX-1 Standard: 2x RS232, USB,4 I/4 O, Ethernet
  • IM01.EX-2 Analog output 4-20mA/0-10V
  • IM01.EX-3 12 I/12 O - digital
  • IM01.EX-4 Profibus DP
  • IM01.EX-5 PROFINET
  • IM01.EX-6 CANopen (available soon)
  • IM01.EX-7 DeviceNet (available soon)
  • IM01.EX-8 RS485
  • IM01.EX: ETHERNET IP (available soon)
Multifunctional Software
Indicator software allows carrying out processes such as weighing, parts counting, dosing, and percent weighing. Indicator’s system of information is based on databases (such as: users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety. The interfaces enable cooperation between the indicator and the accessories intended for operation in the hazardous and non-hazardous areas. Accessories: barcode scanners, printers, external displays, control buttons, light signalling towers and other controlling/signalling devices. The indicator can cooperate with systems for automatic process control and superior IT systems.
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datasheet
OIML Class

III

 

Maximum quantity of divisions from converter

100 000

 

Maximum quantity of verification units

6000 e

 

Minimum volatge per verification unit

0,4 µV

 

Minimum load cell impedance

80 Ω

 

Maximum load cell impedance

1200 Ω

 

Maximum increase of signal

19,5 mV

 

Connection of load cells

4 or 6 wires + shield

 

Display

5” graphic colour

 

Device dimensions

329×231×120

 mm

Packaging dimensions

640×310×220

 mm

Net weight

7,8

 kg

Gross weight

10,5

 kg

Protection class

IP 66 / IP 68

 

Housing

Stainless steel

 

ATEX Certification

II 2G Ex ib IIC T4 Gb (gases)
II 2D Ex ib IIIC T60ºC Db (dusts)

 

Working in zones

1, 2 (gases); 21, 22 (dusts)

 

Communication interface

2×RS232, RS485

 

Operating temperature

-10 — +40

 °C

CE
2 years warranty
Scales with ATEX certificate
360°

Videos
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
Software Manual - CBCP 02
Software Manual - CBCP 02
View
View
Download
Download
(1.18 MB)
Start up Guide
Start up Guide
View
View
Download
Download
(1.57 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
View
View
Download
Download
(0.99 MB)
User Manual - PUEHX5.EX
User Manual - PUEHX5.EX
View
View
Download
Download
(1.79 MB)
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
View
View
Download
Download
(2.00 MB)
Software Manual - PUEHX5.EX
Software Manual - PUEHX5.EX
View
View
Download
Download
(3.50 MB)
User Manual - IM01.EX
User Manual - IM01.EX
View
View
Download
Download
(0.88 MB)
User Manual - PM01.EX
User Manual - PM01.EX
View
View
Download
Download
(0.65 MB)
User Manual - PROFINET communication protocol of PUE HX5.EX
User Manual - PROFINET communication protocol of PUE HX5.EX
View
View
Download
Download
(1.89 MB)
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
View
View
Download
Download
(0.88 MB)
Conformity Declaration
Conformity Declaration
View
View
Download
Download
(0.04 MB)
IECEx Quality Assessment
IECEx Quality Assessment
View
View
Download
Download
(0.25 MB)
Notyfication of Quality Assurance
Notyfication of Quality Assurance
View
View
Download
Download
(1.61 MB)
Weighing Solutions for Hazardous Areas
Weighing Solutions for Hazardous Areas
View
View
Download
Download
(13.16 MB)
PUE HX5.EX Weighing Terminal
PUE HX5.EX Weighing Terminal
View
View
Download
Download
(1.70 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
View
View
Download
Download
(2.23 MB)
Terminals and Platforms
Terminals and Platforms
View
View
Download
Download
(3.72 MB)
Download
Drivers

Plik GSD Profibus (1.321 KB)

GSD do Profinet (4.574 KB)

Accessories
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩