Balance mono capteur HX5.EX-1.60.C3

Radwag Les Balances Electroniques
Selected language Français
Balance mono capteur HX5.EX-1.60.C3
This image is for reference only.

Balance mono capteur HX5.EX-1.60.C3

Code produit: WW-006-0014
Change the model (15)
done
Max: 60kgd: 20g

 500×700mm
expand_more
Max: 1,5kgd: 0,5g

 300×300mm
Max: 3kgd: 1g

 300×300mm
Max: 6kgd: 2g

 300×300mm
Max: 15kgd: 5g

 500×700mm
Max: 15kgd: 5g

 300×300mm
Max: 15kgd: 5g

 400×500mm
Max: 30kgd: 10g

 400×500mm
Max: 30kgd: 10g

 500×700mm
Max: 30kgd: 10g

 300×300mm
Max: 60kgd: 20g

 400×500mm
Max: 150kgd: 50g

 400×500mm
Max: 150kgd: 50g

 500×700mm
Max: 300kgd: 100g

 400×500mm
Max: 300kgd: 100g

 500×700mm
Capacité maximale [Max]: 60 kg
Précision de lecture: 20 g

close
Change the model:
Balance mono capteur HX5.EX-1.1,5.F1
Balance mono capteur HX5.EX-1.3.F1
Balance mono capteur HX5.EX-1.6.F1
Balance mono capteur HX5.EX-1.15.C3
Balance mono capteur HX5.EX-1.15.F1
Balance mono capteur HX5.EX-1.15.C2
Balance mono capteur HX5.EX-1.30.C2
Balance mono capteur HX5.EX-1.30.C3
Balance mono capteur HX5.EX-1.30.F1
Balance mono capteur HX5.EX-1.60.C2
Balance mono capteur HX5.EX-1.60.C3
Balance mono capteur HX5.EX-1.150.C2
Balance mono capteur HX5.EX-1.150.C3
Balance mono capteur HX5.EX-1.300.C2
Balance mono capteur HX5.EX-1.300.C3
Select all
Voir
Download
Pour Comparer Recherche avancée
Description
Les balances de la série HX5.EX sont les appareils modernes de mesure qui rendent possible le pesage précis et rapide dans les zones explosibles 1/21 et 2/22. La construction des balances HX5.EX contient les composants électroniques qui assurent l’haute précision et la répétabilité parfaite de mesure. L’utilisateur peut choisir le type de la balance qui satisfait ses propres exigences utilitaires grâce au vaste choix des dimensions et des étendues de pesage des plate-formes de balance ayant les paramètres métrologiques excellents.

Même la version de base de la balance est équipée de 2 interfaces séquentielles à sécurité intrinsèque de communication RS232 et 1 interface RS 485. Les interfaces permettent la coopération avec les accessoires conçus pour le travail dans les zones explosibles. La possibilité d’ajout des entrées et des sorties digitales à la balance étend la gamme d’appareils compatibles avec le terminal. Grâce à cette possibilité, elle peut coopérer avec les éléments d’automatique conformément à la directive ATEX.  

De plus, il existe la possibilité de profiter du module supplémentaire IM01.EX installé hors de la zone explosible. Le module IM01.EX augmente le nombre des interfaces accessibles: Ethernet, USB, les sorties analogiques 4-20mA/0- 10V, Profibus DP et les entrées/les sorties digitales supplémentaires. Grâce à eux, la balance peut coopérer avec: les lecteurs de code barres, les imprimantes, les afficheurs externes de masse, les touches de commande, la signalisation lumineuse acoustique, d’autres appareils signalisation commande les systèmes de régulation automatique, les systèmes de commande de processus et les systèmes informatiques principaux.  

Les balances sont alimentées par l’alimentateur PM01.EX. Il peut être connecté non seulement aux sources de tension qui se trouvent dans la zone menacée par une explosion mais aussi hors cette zone. Le logiciel étendu rend possible la réalisation de beaucoup de fonctions liées à la mesure de masse, par exemple: le comptage de pièces, les pesages de contrôle, les fonctions de mesures statistiques.

Les balances offrent l’interface conviviale d’utilisateur avec la possibilité de sa configuration à l’aide de widgets et le grand afficheur en couleurs de haute résolution rendent possible la transmission facile d’informations sur l’état actuel du processus réalisé. En outre, le bargraphe en couleurs indique clairement si le résultat du pesage se situe dans les seuils déclarés, ce qui augmente considérablement l’efficacité du travail avec l'appareil.  
 
Paramètres Techniques
Capacité maximale [Max]

60

 kg

Capacité minimale [Min]

400

 g

Précision de lecture

20

 g

Étendue de tare

-60

 kg

Classe de précision OIML

III

 

Afficheur

5” graphique couleurs

 

Longueur de câble

2,5

 m

Dimension du plateau

500×700

 mm

Dimensions de colis

800×950×270

 mm

Masse nette

28,7

 kg

Masse brute

32,7

 kg

Degré de protection

IP 65 construction, IP 66/68 terminal

 

Construction

acier pulvériséeacier St3S

 

Matériel du plateau

Acier inoxydable AISI304

 

Certification ATEX

II 2G Ex ib IIB T4 Gb

 

Certification IECEx

Ex ic IIB T4 Gc

 

Terminal

PUE HX5.EX-1

 

Interface de Communication

2×RS232, RS485

 

Alimentation

100 – 240 V AC 50/60 Hz

 

Prise de courant maximale

15 W

 

Température du travail

-10 – +40

 °C

Humidité relative d'air

10% – 85% RH sans condensation

 

CE
Légalisation Extra payment
for verification
2 ans de garantie
Les balances avec le certificat ATEX
Scales with IECEx certificate
Fonctions
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
Mode d'emploi - CBCP 02
Mode d'emploi - CBCP 02
Voir
Voir
Download
Download
(0.25 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(1.57 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Voir
Voir
Download
Download
(0.99 MB)
Mode d'emploi - PUEHX5.EX
Mode d'emploi - PUEHX5.EX
Voir
Voir
Download
Download
(1.66 MB)
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
Software Manual - EtherNet/IP communication protocol of PUE HX5.EX
Voir
Voir
Download
Download
(2.00 MB)
Software Manual - PUEHX5.EX
Software Manual - PUEHX5.EX
Voir
Voir
Download
Download
(3.50 MB)
User Manual - HX5.EX
User Manual - HX5.EX
Voir
Voir
Download
Download
(2.28 MB)
Mode d'emploi - PM01.EX
Mode d'emploi - PM01.EX
Voir
Voir
Download
Download
(0.95 MB)
Mode d'emploi - PROFINET
Mode d'emploi - PROFINET
Voir
Voir
Download
Download
(1.02 MB)
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
Software Manual - PROFIBUS communication protocol of PUE HX5.EX
Voir
Voir
Download
Download
(0.88 MB)
Déclarations de conformité
Conformity Declaration
Conformity Declaration
Voir
Voir
Download
Download
(0.04 MB)
Certificats
IECEx Quality Assessment
IECEx Quality Assessment
Voir
Voir
Download
Download
(0.25 MB)
Notyfication of Quality Assurance
Notyfication of Quality Assurance
Voir
Voir
Download
Download
(1.61 MB)
Publications et brochures
Solutions de pesage pur les zones menacées par les explosions
Solutions de pesage pur les zones menacées par les explosions
Voir
Voir
Download
Download
(13.17 MB)
PUE HX5.EX Weighing Terminal
PUE HX5.EX Weighing Terminal
Voir
Voir
Download
Download
(1.68 MB)
Modules additionnels

RES Protocole de communication Radwag3

Newsletter

If you wish to receive the latest news about RADWAG products and services, sign up for the newsletter.

More
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩