Balance analytique XA 82/220.5Y

Radwag Les Balances Electroniques
Selected language Français
Obraz
This image is for reference only.

Balance analytique XA 82/220.5Y

Code produit: WL-110-1001
Change the model (2)
done
Max: 82 / 220gd: 0,01 / 0,1mg

 ø90 en ajour + ø85 (en option)mm
expand_more
Max: 120 / 250gd: 0,01 / 0,1mg

 ø90 en ajour + ø85 (en option)mm
Capacité maximale [Max]: 82 / 220 g
Précision de lecture: 0,01 / 0,1 mg

close
Change the model:
Balance analytique XA 82/220.5Y
Balance analytique XA 120/250.5Y
Select all
Voir
Download
Pour Comparer Recherche avancée
Description

Balance analytique XA 82/220.5Y

 
Les balances analytiques XA 5Y, en tant qu’appareils de mesure réputés pour leur haute précision, résolution et bonne répétabilité, sont des éléments clés des équipements des laboratoires pharmaceutiques, physiques, chimiques, biologiques, médicaux et bien d’autres.
 
 
 

Pourquoi la balance XA 5Y mérite-t-elle d’être choisies ?

 

LevelSENSING System – Nivellement semi-automatique

Il indique à l’utilisateur dans quelle direction il doit tourner les pieds pour mettre la balance à niveau. La procedure indiquée étape par étape minimise le risque d’erreurs et réduit considérablement le temps de mise à niveau.
 
 

Chambre de pesée à ouverture manuelle

Ces balances offrent une chambre de pesée à ouverture manuelle qui permet un accès facile aux échantillons et leur placement pratique sur la balance. Cette function, garantissant un contrôle total sur le processus de pesée, est idéale pour ceux qui ont besoin d’un accès rapide à un échantillon.
 
 

Ajustage interne

Un système d’ajustage interne intégré assure un réglage automatique, garantissant une précision à long terme et minimisant le besoin d’intervention manuelle. Grâce à cela, les utilisateurs peuvent être sûrs que la balance fonctionne toujours avec la plus grande précision, quelles que soient les conditions de leur fonctionnement.
 
 
 

Digital Weighing Auditor

s’assure que votre balance est prête à fonctionner. Il permettra une compensation en temps réel de la flottabilité de l’air. De plus, il informera de la nécessité d’effectuer un examen du solde ou un audit périodique de l’exactitude et de la sensibilité du solde.
 
 
 
 

Écran 10 pouces

L’écran plus grand – 10’’ – signifie plus d’informations en un seul endroit. Sur le nouveau terminal ELLIPSIS, vous pouvez même voir 3 écrans, des widgets, des graphiques, des statuts, des notes et un historique de mesure pratique.
 
 
 
 

Une façon sans compromis de vérifier l’utilisateur

Pour la première fois dans l’histoire, la balance vérifiera l’utilisateur à l’aide d’un mot de passe, d’une carte RFID, d’un lecteur d’empreintes digitalesd’un moteur de reconnaissance faciale ou de toute combinaison de ceux-ci.
 
 
 

Ambient Light: des alertes lumineuses – un coup d’oeil et tout est clair

La couleur du rétroéclairage vous informera sur l’état, les résultats du processus, les procédures ou autres alertes. Les méthodes modernes de communication entre la balance et l’utilisateur garantissent efficacité, transparence et commodité dans le travail quotidien.
 
 
 
 
 

Hotspot

Pas d’accès au terminal ou de la place dans une hotte de laboratoire ? Ou peut-être souhaitez-vous faire fonctionner la balance à distance ? Utilisez la balance sur n’importe quel dispositif connecté. Il peut s’agir d’un smartphone, d’une tablette ou d’un ordinateur.
 
 
 

RFID

ELLIPSIS fonctionne avec des étiquettes RFID* qui peuvent être utilisées pour marquer vos produits ou ingrédients de recette dans la base de données. De plus, elles peuvent être utilisées pour identifier l’utilisateur.
 
 
 

Live Note – notez vos conclusions

C’est la première fois que vous ajoutez un mémo vocal à une série de mesures ou à un rapport de procédure. Si vous préférez l’écrire, ELLIPSIS vous permettra d’ajouter une note textuelle.
 
 
 

Handy Library

C’est là que vous verrez une série de mesures récentes ou un rapport prêt pour la signature numérique conformément à 21 CFR Part 11.
 
 
 

Widget

Préparé pour afficher ce dont vous avez le plus besoin en ce moment.
 
 
 

Smart Min Weight

La balance affiche des informations indiquant si la valeur de masse que vous souhaitez peser est inférieure ou supérieure au seuil de pesée minimum.
 
 
 

21 CFR Partie 11

Vous travaillez dans l’industrie pharmaceutique ? Avez-vous besoin d’une signature numérique ?
 
Nous proposons une balance de laboratoire qui, en tant que dispositif autonome, répond aux exigences de 21 CFR Partie 11/ EU BPL Annex 11.

 Sécurité totale des données
 Signatures électroniques
 Validations
– Dossiers électroniques
 Pistes d’audit
 
 
 

Le Modbus TCP/IP

est un de protocoles plus populaires dans le domaine des systèmes de communication industrielle automatisée. Incorporé aux balances 5Y et CY10, en raison de sa capacité à mettre en réseau divers dispositifs, le protocole facilite le travail à des intégrateurs.
 
Le protocole Modbus échange des informations en utilisant un mécanisme de requête-réponse entre un automate programmable industriel API (PLC) qui est un maître et la balances qui est un esclave. Dans les balances 5Y et C10, le protocole Modbus TCP/IP permet, entre autres, les fonctions de lecture de masse, zérotage et tarage de la balance, ainsi que de configuration de la tare et des seuils MIN et MAX.

 
 
 
 

Réglage en deux points

Le réglage, qui s’effectue en deux points de mesure au lieu d’un, augmente la précision de la mesure sur toute la plage de pesée. Qu’est-ce que cela signifie pour vous? Mesure plus précise.
 
 
 
Pesage sous la balance
Les balances achetées après le 15 février 2023 permettront le pesage sous la balance à tout moment après l'achat du dispositif. Achetez simplement un crochet dédié.
 
 
* RFID ISO/IEC 14443 Type A, 13,56 MHz
 
 
Paramètres Techniques
Capacité maximale [Max]

82 / 220

 g

Capacité minimale [Min]

1

 mg

Précision de lecture

0,01 / 0,1

 mg

Échelon de légalisation [e]

1

 mg

Étendue de tare

-220

 g

Répétabilité standard [5% Max]

0,005

 mg

Répétabilité standard [Max]

0,06

 mg

Poids minimal d’echantillon standard (USP)

10

 mg

Poids minimal d’echantillon standard (U=1%, k=2)

1

 mg

Répétabilité admissible [5% Max]

0,012

 mg

Répétabilité admissible [Max]

0,08

 mg

Linéarité

±0,06 / 0,2

 mg

Non-centricité

0,2

 mg

Stabilité de sensibilité

1×10⁻⁶/année×Rt

 

Temps de stabilisation

4

 s

Ajustage

interne (automatique)

 

Classe de précision OIML

I

 

Système de nivellement

semi-automatique – LevelSENSING

 

Afficheur

10″ graphique couleurs écran tactile

 

Porte de la cage de pesée

manuel

 

Élément du kit

Balance analytique, plateau, couvercle de plateau, bague de centrage, couvercle inférieur, pinceau, housse, adaptateur secteur.

 

Dimensions de la chambre de pesée

168×160×228

 mm

Dimension du plateau

ø90 en ajour + ø85 (option)

 mm

Dimensions de colis

750×492×595

 mm

Masse nette

9,8

 kg

Masse brute

16

 kg

Degré de protection

IP 43

 

Interface de Communication

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

 

Alimentation

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 12 – 15V DC 1,6A max*

 

Température du travail

+10 – +40

 °C

Vitesse de changements de température de travail

±0,3 °C / 1 h (±1 °C / 8 h)

 

Humidité relative d'air

20% – 80%

 

Vitesse de changements d'humidité relative d'air

±1% / h (±4% / 8 h)

 

CE
Légalisation Additional fee
for verification
5 ans de garantie
Répétabilité exprimée comme un écart standardisé de 10 placements de chargé.
Temps de stabilisation dépend de conditions externes et de la dynamique du placement d’un poids sur le plateau; déterminé pour le profil FAST.
* L'alimentation électrique peut être connectée à la prise à l'arrière du boîtier de la balance ou au terminal.
360°
Films
Precision and Working Comfort – Operating RADWAG Balances in Every Glove!
5Y Functions: Animal Weighing
5Y Functions: Statistics
5Y Functions: DWA®
5Y Balance and Barcode Scanner – Easy Connection
New Menu Language in 5Y Series Balances: Japanese
5Y Functions: Checkweighing
5Y Functions: Dosing
5Y Functions: Formulations
Percentage deviations
5Y Functions: Weighing
5Y Functions: Parts counting
5Y Functions: Proximity Sensors – Touch-Free Control (Tutorial)
5Y Functions: GLP Procedures – Objective Documentation of Measurements (Tutorial)
Weighing Printout Design in Analytical and Precision Balances (Tutorial)
Impression facile avec Wi-Fi® Thermal Receipt Printer – imprimante de reçus thermique de Radwag
ELLIPSIS – une nouvelle balance de RADWAG
ELLIPSIS – Innovation technologique
Dis-le! Commandes vocales dans la nouvelle balance ELLIPSIS de RADWAG
ELLIPSIS – Scannez ou passez la carte devant le lecteur
Connexion VPN à la balance ELLIPSIS
ELLIPSIS – Connexions illimitées
Connexion de la balance série 5Y a l’imprimante RTP-UEW80 via Wi-Fi®®
Microbalance XA 5Y – Déballage et mise en service (Tutoriel)
NOUVEAUTE : Première imprimante de reçus de production RADWAG!
Solution complète pour la mesure de la masse en pharma
New AS and PS 5Y Balances – Autotest (Tutorial)
Fonctions
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Moveable range

Moveable range

Dual range analytical balances can be equipped with much more precise measuring range but only in very limited part of max capacity and only from zero load. A new technology introduced by RADWAG allows for moving this limited range till max capacity of the balance is reached. Such solution has been named as: Moveable range.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
User Manual
User Manual
Voir
Voir
Download
Download
(2.36 MB)
User Manual
User Manual
Voir
Voir
Download
Download
(1.24 MB)
Software Manual
Software Manual
Voir
Voir
Download
Download
(1.23 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(4.76 MB)
Déclarations de conformité
Conformity Declarations
Conformity Declarations
Voir
Voir
Download
Download
(0.04 MB)
Publications et brochures
Laboratory balance cleaning
Laboratory balance cleaning
Voir
Voir
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Voir
Voir
Download
Download
(1.64 MB)
Lexique des Termes Élémentaires de Métrologie
Lexique des Termes Élémentaires de Métrologie
Voir
Voir
Download
Download
(17.18 MB)
RFID
RFID
Voir
Voir
Download
Download
(0.68 MB)
Hybrid Protective Glass
Hybrid Protective Glass
Voir
Voir
Download
Download
(1.86 MB)
Laboratory Balances
Laboratory Balances
Voir
Voir
Download
Download
(1.68 MB)
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Checking and calibrating fixed volume and adjustable volume piston pipettes using a gravimetric method
Voir
Voir
Download
Download
(5.49 MB)
XA 5Y Micro and Analytical Balances
XA 5Y Micro and Analytical Balances
Voir
Voir
Download
Download
(4.47 MB)
ELLIPSIS Balances de laboratoire série 5Y
ELLIPSIS Balances de laboratoire série 5Y
Voir
Voir
Download
Download
(29.83 MB)
Accessoires
R-LAB

Accessoires

Modules additionnels

RES Protocole de communication Radwag3
Module de conformité à 21 CFR partie 113

Newsletter

Inscrivez-vous à la Newsletter de RADWAG pour tout savoir sur nos nouveautés.

Voir plus
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩
close