WLC 6/A2/C/2 Precision Balance

Selected language
WLC 6/A2/C/2 Precision Balance
This image is for reference only.

WLC 6/A2/C/2 Precision Balance

Product code: WL-217-0014
Change the model (8)
done
Max: 6kgd: 0,1g

 195×195mm
expand_more
Max: 0,6kgd: 0,01g

 128×128mm
Max: 0,6kgd: 0,01g

 128×128mm
Max: 1kgd: 0,01g

 195×195mm
Max: 1kgd: 0,01g

 195×195mm
Max: 2kgd: 0,01g

 195×195mm
Max: 2kgd: 0,01g

 195×195mm
Max: 6kgd: 0,1g

 195×195mm
Maximum capacity [Max]: 6 kg
Readability [d]: 0,1 g

close
Change the model:
WLC 0,6/A1/C/2 Precision Balance
WLC 0,6/A1/C/2/IO Precision Balance
WLC 1/A2/C/2 Precision Balance
WLC 1/A2/C/2/IO Precision Balance
WLC 2/A2/C/2 Precision Balance
WLC 2/A2/C/2/IO Precision Balance
WLC 6/A2/C/2 Precision Balance
WLC 6/A2/C/2/IO Precision Balance
Select all
View
Download
Add to compare Advanced Search
Overview
 

WLC 6/A2/C/2 Precision Balance

 
Precision balances enable fast and accurate determination of mass in laboratory and industry. The devices are equipped with an internal battery which allows their operation in places where there is no access to the mains.
 
 
 
 

Communication interfaces

The balance features a stainless steel weighing pan, and a backlit LCD guaranteeing clear weighing result presentation. They also have an option of automatic internal adjustment.
 
Communication interfaces: 2×RS232, USB type A, USB type B. The interfaces enable cooperation with peripheral devices, e.g. printer, computer, USB flash drive, additional display. The WLC balances feature real-time clock and ALIBI memory. Optionally, they can be equipped with
4 IN / 4 OUT.

Internal rechargeable cell comes standard with WLC C/2 series balance!
 
 

 
 
Internal adjustment/calibration system!
 

 
 
 
Datasheet
Maximum capacity [Max]

6

 kg

Minimum load

5

 g

Readability [d]

0,1

 g

Verification unit [e]

1

 g

Tare range

-6

 kg

Repeatability

0,15

 g

Linearity

±0,2

 g

Stabilization time

3

 s

Adjustment

internal (automatic)

 

OIML Class

II

 

Leveling system

manual

 

Display

LCD (backlit)

 

Weighing pan dimensions

195×195

 mm

Packaging dimensions

430×270×190

 mm

Net weight

3,6

 kg

Gross weight

4

 kg

Protection class

IP 43

 

Communication interface

2×RS232, USB-A, USB-B

 

Power supply

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Balance: 10 – 15VDC 0,6A max

 

Operation time on batteries

15 h (average time)

 

Operating temperature

+15 – +30

 °C

Relative humidity

10% – 85% RH no condensation

 

CE
Verification Extra payment
for verification
Videos
Complete Solutions for Mass Measurement in Pharma Industry
Functions
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Internal battery

Internal battery

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
Documentation
Data Sheet Data Sheet
Data Sheet

View
View
Download
Download

Choose more product:
View View DownloadDownload
User Manual - CBCP 01
User Manual - CBCP 01
View
View
Download
Download
(0.30 MB)
Software Manual - WLC A
Software Manual - WLC A
View
View
Download
Download
(1.66 MB)
User Manual - WLC
User Manual - WLC
View
View
Download
Download
(1.27 MB)
Start up Guide
Start up Guide
View
View
Download
Download
(1.13 MB)
Conformity Declaration
Conformity Declaration
View
View
Download
Download
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
View
View
Download
Download
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
View
View
Download
Download
(1.64 MB)
Laboratory Balances
Laboratory Balances
View
View
Download
Download
(1.68 MB)
Download
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessories
Radwag Balances and Scales
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances and Scales. All rights reserved.

Select language

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Company name:
Name:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩