Bilancia di precisione PS 8100.X7.M.CPC

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Bilancia di precisione PS 8100.X7.M.CPC
This image is for reference only.

Bilancia di precisione PS 8100.X7.M.CPC

Codice prodotto: WK-313-0005
Modifica del modello (5)
done
Max: 8100gd: 0,1g

 195×195mm
expand_more
Max: 750gd: 0,01g

 128×128mm
Max: 2100gd: 0,1g

 195×195mm
Max: 4500gd: 0,1g

 195×195mm
Max: 6100gd: 0,1g

 195×195mm
Portata massima [Max]: 8100 g
Divisione [d]: 0,1 g

close
Modifica del modello:
Bilancia di precisione PS 750.X7.CPC
Bilancia di precisione PS 2100.X7.M.CPC
Bilancia di precisione PS 4500.X7.M.CPC
Bilancia di precisione PS 6100.X7.M.CPC
Bilancia di precisione PS 8100.X7.M.CPC
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali

Bilancia di precisione PS 8100.X7.M.CPC

 
Lo scopo della bilancia è quello di controllare le merci preconfezionate (PGC), quindi è necessaria la legalizzazione.
Si consiglia di ordinare una bilancia con la legalizzazione appropriata.
 
PS X7.M è una serie di bilance avanzate di alta precisione con elevata capacità di carico, basate sulla tecnologia 

MONO

BLOCK
. Il design innovativo delle bilance PS X7.M è caratterizzato da un nuovo attacco del piatto a punto singolo, che garantisce un'ottima geometria della bilancia e riduce al minimo l'eccentricità. Il design a labirinto assicura un'elevata resistenza alla contaminazione.
 
 
 

Modulo di pesatura

L'uso della tecnologia

MONO

BLOCK
consente di pesare carichi con una precisione di d=0,01 g con una capacità di carico fino a 10 kg. La base rigida assicura la stabilità del sistema di pesatura e un'elevata resistenza agli urti. Il sistema di regolazione interno garantisce precisione ed elevata ripetibilità delle misure. Il rapporto di massa del peso interno consente la valutazione su tutto il campo di misura.
 
 
 

Caratteristiche principali della serie PS X7.M:

  • precisione di d=0,01g con una capacità di carico fino a 10 kg,
  • elevata resistenza ai fattori esterni,
  • garanzia di stabilità e ripetibilità nel tempo,
  • utilizzo della tecnologia

    MONO

    BLOCK
    ,
  • regolazione interna nell'intero campo di misura,
  • ampi database e memoria ALIBI,
  • pannello tattile ergonomico a colori da 7 pollici,
  • funzionamento senza contatto.
 
 
 

Database

Nelle bilance di precisione PS X7.M, le informazioni sono organizzate in 11 distinti database che permettono l’utilizzo di diversi operatori con database riportanti i dati di svariati prodotti. I risultati delle pesate, una volta registrati, posso essere utilizzati per eseguire successivamente valutazioni dei dati.
 
I dati sono registrati in 11 distinti database:
  • Prodotti (5.000 prodotti)
  • Utenti (100 utenti)
  • Imballaggi (100 imballaggi)
  • Clienti (1.000 clienti)
  • Ricette (100 ricette)
  • Rapporti delle ricette (500 rapporti)
  • Condizioni ambientali (10.000 record)
  • Pesate (50.000 record)
  • Memoria Alibi (512.000 record)
  • Rapporti di controllo (1.000 rapporti)
  • Tare medie (1.000 rapporti).
 
 
 

Memoria ALIBI

Le bilance di precisione PS X7.M sono dotate di una memoria ALIBI, che garantisce la sicurezza in quanto registra automaticamente le misure e consente di visualizzare, copiare e archiviare i dati. La memoria ALIBI consente di memorizzare fino a 512.000 record di pesata.
 
 
 

Nuove possibilità

Le bilance di precisione PS X7.M consentono di progettare la disposizione delle informazioni sul display attraverso un'ampia scelta di widget. La personalizzazione del display della bilancia PS X7.M consente di accedere alle informazioni e ai risultati operativi direttamente dal pannello principale del display. Le bilance di precisione PS X7.M sono dotate di diverse interfacce di comunicazione: 2 x RS232, USB-A, USB-B, EthernetWi-Fi®. L'alloggiamento della bilancia è in plastica e il piatto è in acciaio inox.
 
L'interfaccia USB consente di trasferire e copiare rapidamente i risultati del lavoro (misure, rapporti, database) su un PC o su un'altra bilancia. È possibile gestire in remoto i dati della bilancia.
 
 
 
Sistema THBR 2.0
Le bilance funzionano con il sistema THBR 2.0 per il monitoraggio delle condizioni ambientali.
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications

Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
Specifiche
Portata massima [Max]

8100

 g

Portata minima [Min]

5

 g

Divisione [d]

0,1

 g

Intervallo di verifica della bilancia [e]

0,1

 g

Campo di tara

-8100

 g

Portata minima (secondo USP)

10

 g

Portata minima (U=1%,k=2)

1

 g

Ripetibilita (Max)

0,01

 g

Ripetibilita (5% Max)

0,005

 g

Linearità

±0,02

 g

Tempo di stabilizzazione

1,5

 s

Calibrazione

internal (automatic)

 

Classe OIML

II

 

Sistema di livellamento

manual

 

Display

7″ graphic colour touchscreen

 

Componenti del kit

Balance, weighing pan, weighing pan shield, power supply

 

Dimensione piatto

195×195

 mm

Device dimensions

333x206x107

 mm

Dimensioni del pacco

476×381×346

 mm

Peso netto

5,7

 kg

Peso lordo

7,3

 kg

Punteggio IP

IP 43

 

Capacita del database

Products, Users, Packaging, Customers, Formulations, Formulations reports, Ambient Conditions, Weighings, Alibi memory, Control reports, Average tares

 

Operazione senza comandi diretti

2 IR Sensors

 

Interfaccia

2×RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

 

Alimentatore

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Balance: 12 – 15V DC 0,8A max

 

Consumo di energia

4 W

 

Ambiente di lavoro

+10 – +40

 °C

Umidità relativa

40% – 80%

 

CE
Verifica Additional fee
for verification
La ripetibilità è espressa come deviazione standard di 10 posizionamenti dello standard di massa.
Il tempo di stabilizzazione dipende dalle condizioni esterne e dalla dinamica di posizionamento del carico sul piatto; specificato per il profilo FAST.
Funzioni
Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Ambient conditions monitoring

Ambient conditions monitoring

The possibility of cooperation with the THBR 2.0 system
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
Packaged Goods Control

Packaged Goods Control

Pre-packaged Goods Control mode enables to collect weighings from RADWAG-designed weighing instruments, carry out control and generate PGC reports. Different types of weighing instruments can be combined into a network. The control can be started on a balance or via computer software. It is automatically finished after a respective quantity of packages is verified.
Collected data allows you to assess quality of produced pre-packaged goods and their conformity with:
- internal quality control system;
- 'Pre-Packaged Goods' regulation of 7th May 2009 (Journal of Laws No 91, item 740), on the requirements concerning quantity inspection of pre-packaged goods control, which inspection is to be carried out by means of random selection of the measurements results and sending those results to pre-packaged goods control procedure.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Mass for titrator

Mass for titrator

'Mass value for a titrator' working mode enables establishing connection between the weighing device and a titrator. The titrator receives information about the quantity of dispensed mass, and the weighing instrument receives a signal to start subsequent weighing.

Wi-Fi®

Wi-Fi®

Thanks to wireless communication between the computer and a balance, it is possible to use a balance inside a laminar flow hood and a fume cupboard.

Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Laboratory balance cleaning
Laboratory balance cleaning
Vista
Vista
Salva
Salva
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Vista
Vista
Salva
Salva
(1.64 MB)
USB Free Link - Direct Balance-PC Communication
USB Free Link - Direct Balance-PC Communication
Vista
Vista
Salva
Salva
(2.07 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
Defined Weighing Profiles
Defined Weighing Profiles
Vista
Vista
Salva
Salva
(1.36 MB)
Software
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩