Max: 60kgd: 1g

 400×500mm
expand_more
Max: 10kgd: 0,01g

 200×185mm
Max: 15kgd: 0,01g

 200×185mm
Max: 25kgd: 0,1g

 350×260mm
Max: 35kgd: 0,1g

 350×260mm
Max: 60kgd: 0,5g

 400×500mm
Max: 60kgd: 0,1g

 400×500mm
Max: 120kgd: 0,2g

 400×500mm
Maxima capacidad [Max]: 60 kg
Legibilidad [d]: 1 g

close
Change the model:
Balanza de precisión C32.10.PM
Balanza de precisión C32.15.PM
Balanza de precisión C32.25.PM
Balanza de precisión C32.35.PM
Balanza de precisión C32.60.PM.1
Balanza de precisión C32.60.PM.05
Balanza de precisión C32.60.PM
Balanza de precisión C32.120.PM
Select all
Para comparar Búsqueda avanzada
Descripción
 

Balanza de precisión C32.60.PM.1

 
Balanzas PM RADWAG: precisión de laboratorio en condiciones industriales 
 
 
 
 

La tecnología mejorada

  • Posibilidad de pesar cargas de hasta 120 kg en un platillo grande con alta precisión y buena repetibilidad,
  • mínimo error de excentricidad en todo el rango,
  • medición rápida y estable (alcanzable en 1 segundo),
  • estabilidad de los parámetros en el tiempo y en el transporte,
  • dimensiones del platillo de pesaje adaptadas a la precisión de la balanza
son los sellos distintivos de las balanzas PM de RADWAG. Todo esto es el resultado de la aplicación de un sistema de medición innovador basado en la tecnología mejorada RADWAG 

MONO

BLOCK®
.

El cambio de la estructura monobloque permitió trabajar con una precisión de 0,01 g con una capacidad de carga de 20 kg y de 0,2 g con una capacidad de carga de 120 kg, repetibilidad a partir de 0,01 g y resistencia a los cambios de las condiciones ambientales.

 

 

Las balanzas PM también son:

  • construcción sólida basada en un monobloque más grande y alto,
  • sistema de protección de sobrecarga de 4 puntos incorporado,
  • grado de protección IP 43,
  • calibración interna,
  • Pantalla de color 5",
  • fácil puesta en marcha, manejo intuitivo y ergonomía de trabajo.
 
 
 
 

Aplicación

Las balanzas PM no solo garantizan una lectura precisa y una medición rápida, sino que también son universales y, por lo tanto, se pueden utilizar en muchos sectores industriales.

La dosificación, la formulación y el contaje de piezas son solo algunas de las posibles aplicaciones de estos versátiles dispositivos.

Las balanzas PM encontrarán destinatarios allí donde se necesiten dispositivos de pesaje de alta precisión y gran capacidad de carga.
 
 
 
 
 
* RFID ISO/IEC 14443 Type A, 13,56 MHz
 
 
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Datos tecnicos
Parámetros metrológicos
Paramètros físicos
Construcción
Interface de comunicación
Parámetros electricos
Condiciones ambientales
Maxima capacidad [Max]

60

 kg

Minima capacidad

10

 g

Precarga

6

 kg

Legibilidad [d]

1

 g

División de legalización [e]

1

 g

Rango de tara

-60

 kg

Pesada mínima usp

820

 g

Pesada mínima

82

 g

Repetibilidad (Max)

0,8

 g

Repetibilidad (5% Max)

0,41

 g

Linealidad

±3

 g

Tiempo de estabilización

1

 s

Calibración

interna (automatica)

 

Clase OIML

II

 

Sistema de nivelación

manual

 

Pantalla

5” gráfico color

 

Dimensión de platillo

400×500

 mm

Dimensiones de embalaje

710×610×240

 mm

Masa neta

22

 kg

Masa bruta

25,5

 kg

Grado de protección

IP 43

 

Conectividad

2×RS232, USB-A, USB-B, Ethernet, 4 IN / 4 OUT (digitales), Wi-Fi®

 

Alimentacion

Adapter: 100 – 240V AC 50/60Hz 0,6A; 12V DC 1,2A
Balanza: 10 – 12V DC 1A max

 

Temperatura de trabajo

+10 – +40

 °C

CE
Legalización Additional fee
for verification
Wi-Fi® es una marca registrada de Wi-Fi Alliance®.
La repetibilidad se expresa como una desviación estándar de 10 posiciones de carga.
El tiempo de estabilización depende de las condiciones externas y la dinámica de colocar los pesos en el platillo; especificado para el perfil FAST.
Precarga – un valor igual a ±10% de la carga máxima [Max] de la balanza verificada. Es posible poner en marcha la balanza con la masa colocada sobre el platillo igual al valor máximo de precarga.
360°
Vídeos
Impresión fácil con las impresoras térmicas de recibos Wifi® de RADWAG
Complete Solutions for Mass Measurement in Pharma Industry
Funciones
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentación
Tarjetas de productos
Data Sheet Data Sheet
Data Sheet

Ver
Ver
Guardar
Guardar

Choose more product:
Ver Ver GuardarGuardar
Manual de usuario
Start up Guide
Start up Guide
Ver
Ver
Guardar
Guardar
(1.69 MB)
Manual de instrucciones
Manual de instrucciones
Ver
Ver
Guardar
Guardar
(0.31 MB)
Declaraciones de conformidad
Conformity Declaration
Conformity Declaration
Ver
Ver
Guardar
Guardar
(0.04 MB)
Publicaciones y folletos
Laboratory balance cleaning
Laboratory balance cleaning
Ver
Ver
Guardar
Guardar
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Ver
Ver
Guardar
Guardar
(1.64 MB)
PM balanzas de precision
PM balanzas de precision
Ver
Ver
Guardar
Guardar
(5.03 MB)
Diccionario de Términos Metrológicos Básicos
Diccionario de Términos Metrológicos Básicos
Ver
Ver
Guardar
Guardar
(17.15 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Ver
Ver
Guardar
Guardar
(2.23 MB)
Programas
Drivers

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accesorios
R-LAB

Accesorios

Módulos adicionales

RES Protocolo de comunicación Radwag2
WX-016-0154 RES level: 0,1,2 (PUE HY10)
WX-016-0212 RES level: 0,1,2 (WLY, PUE71)
WX-016-0264 RES level: 0,1,2 (4Y, 5Y)
WX-016-0265 RES level: 0,1,2 (X2, X7)
WX-016-0292 RES level: 0,1,2 (PUE HX7)
WX-016-0293 RES level: 0,1,2 (PUE C32)

Character communication protocol is designed for communication between RADWAG balance and external device via RS232, Ethernet or Wi-Fi®®* interfaces.
 
The protocol consists of commands sent from the external device to the balance and responses sent from the balance to the device. 
 
Responses are sent from the balance each time a command is received as a response to the command. 
 
The commands that make up the communication protocol allow you to obtain information about the status of the balance and ways to influence its operation, for example, they allow you to receive weighing results from the balance, control the display, etc.

Newsletter

Suscríbete al newsletter si quieres recibir información sobre las novedades de RADWAG.

Ver más

© 2024 RADWAG USA L.L.C.. All rights reserved.

All proprietor's rights do the materials placed in the server are in possession of RADWAG USA L.L.C. and are not to be copied, processed and utilized in commercial purpose unless agreed with RADWAG USA L.L.C. .

RADWAG USA L.L.C.
19599 NE 10th Pl Suite E, Miami, FL 33179, USA
tel.: 13056513522

Selecionar idioma

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Français Français
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nombre de empresa
Nombre:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩
close
By using this website, you consent to our use of cookies in accordance with the principles of our Privacy Policy.    OK