Bilancia di precisione WLY 1/D2

Radwag Bilance e sistemi di pesatura
Selected language Italiano
Bilancia di precisione WLY 1/D2
This image is for reference only.

Bilancia di precisione WLY 1/D2

Codice prodotto: WL-219-0003
Modifica del modello (15)
done
Max: 1kgd: 0,01g

 195×195mm
expand_more
Max: 2kgd: 0,01g

 195×195mm
Max: 6kgd: 0,1g

 195×195mm
Max: 6kgd: 0,1g

 300×300mm
Max: 6kgd: 0,1g

 300×300mm
Max: 10kgd: 0,1g

 195×195mm
Max: 12kgd: 0,2g

 300×300mm
Max: 12kgd: 0,2g

 300×300mm
Max: 20kgd: 0,1g

 195×195mm
Max: 30kgd: 0,5g

 300×300mm
Max: 30kgd: 0,5g

 300×300mm
Max: 60kgd: 1g

 400×500mm
Max: 60kgd: 1g

 400×500mm
Max: 120kgd: 2g

 400×500mm
Max: 120kgd: 2g

 400×500mm
Portata massima [Max]: 1 kg
Divisione [d]: 0,01 g

close
Modifica del modello:
Bilancia di precisione WLY 1/D2
Bilancia di precisione WLY 2/D2
Bilancia di presizione WLY 6/D2
Bilancia di precisione WLY 6/F1/R
Bilancia di precisione WLY 6/F1/K
Bilancia di precisione WLY 10/D2
Bilancia di precisione WLY 12/F1/K
Bilancia di precisione WLY 12/F1/R
Bilancia di precisione WLY 20/D2
Bilancia di precisione WLY 30/F1/R
Bilancia di precisione WLY 30/F1/K
Bilancia di precisione WLY 60/C2/R
Bilancia di precisione WLY 60/C2/K
Bilancia di precisione WLY 120/C2/R
Bilancia di precisione WLY 120/C2/K
Select all
Vista
Salva
Aggiungere a confrontare
Caratteristiche generali

Bilancia di precisione WLY 1/D2

 
Le bilance multifunzione WLY sono state realizzate per eseguire pesate veloci ed affidabili con il supporto di un moderno terminale serie PUE7.
 
 
 

Applicazione

Le bilance sono caratterizzate da una struttura funzionale e permettono la il massimo livello di automazione nella gestione dei dati. Oltre il modo di pesata semplice le bilance permettono di eseguire operazioni di conteggio pezzi, etichettatura e di preaparazione di formulati.
Il software universale implementato nel termnale permette alla bilancia di dialogare con lettori di codici a barre, stampanti per scontrini, stampanti per etichette scanner RFID e di connettere periferiche per PC (inclusi mouse, tastiere, e dispositivi di memoria USB) tramite le interfacce integrate nelle bilance seriale RS232, USB ed Ethernet.
 
 
 

Progetto e funzionalita’

Le bilance serie WLY dispongono di un piatto di pesata in acciaio inox e di un terminale comprendente un display a colori touch screen da 5,7” TFT ed una tastiera a membrana integrati. Il sistema e predisposto per la connessione di un basamento addizionale e dispone delle seguenti funzioni:
  • programmazione e personalizzazione del display e dei comandi funzione
  • programmazione dei sensori di prossimita ad infrarossi,
  • definizione dei formati di stampa,
  • definizione delle linee di testo esplicative che appaiono sul display.
 
 
 

Funzionalita’ del Software:

  • differenti modi di lavoro disponibili: pesata semplice, conteggio pezzi, pesata percentuale, formulazione, pesata di animali;
  • generazione di etichette standardizzate per ogni songolo prodotto:
  • generazione di etichette C per per contenitori „cumulativi”;
  • generazione di etichette CC per contenitori cpntenenti sub contenitori cumulativi;
  • tre diversi modi di generazione etichette C e CC:
    • manuale,
    • in funzione dello stato di un prodotto,
    • in funzione del raggiungimento del peso di un prodotto;
  • controllo peso (con limiti inferiori e superiori +/-);
  • identificazione del prodotto utilizzando le codifiche EAN-13 ed EAN-128;
  • accesso ai database operatori, prodotti, materiali grezzi, clienti, pesate eseguite, variabili generali, e tare.
Le bilance WLY permettono una semplice ricerca di un prodotto per mezzo di un lettore di codice a barre connesso direttamente alla bilancia. Questa funzione aumenta considerevolmente la funzionalita del sistema. Il terminale puo essere collegato a software per PC "LABEL EDITOR". Il software e gestibile sia attraverso la comunicazione seriale RS 232 o tramie una connesione ETHERNET.
 
Le bilance serie WLY sono disponibili anche in versione „dual range” o doppia scala (non-verificate metricamente) con un piccolo sovraprezzo.
 
 
Stainless Steel in RADWAG products
Learn about the use and maintenance of stainless steel products:
Stainless Steel in RADWAG products. Standard and special applications
Specifiche
Portata massima [Max]

1

 kg

Portata minima [Min]

-

 

Divisione [d]

0,01

 g

Intervallo di verifica della bilancia [e]

-

 

Campo di tara

-1

 kg

Ripetibilita

0,03

 g

Linearità

±0,03

 g

Tempo di stabilizzazione

3

 s

Calibrazione

external

 

Classe OIML

-

 

Sistema di livellamento

manual

 

Display

5,7” Resistive Color Touchscreen

 

Dimensione piatto

195×195

 mm

Dimensioni del pacco

530×310×150

 mm

Peso netto

2,7

 kg

Peso lordo

3,6

 kg

Punteggio IP

IP 43

 

Interfaccia

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Alimentatore

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2,4A
Balance: 10 – 28V DC 1A max

 

Ambiente di lavoro

+15 – +30

 °C

Temperatura di stoccaggio

-25 – +70

 °C

Umidità relativa

10% – 85% RH no condensation

 

CE
La ripetibilità è espressa come deviazione standard di 10 posizionamenti dello standard di massa.
Il tempo di stabilizzazione dipende dalle condizioni esterne e dalla dinamica di posizionamento del carico sul piatto; specificato per il profilo FAST.
Video
Stampa facile con l’RTP-UEW80 con Wi-Fi®®
Complete Solutions for Mass Measurement in Pharma Industry
Funzioni
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Plus/Minus Control

Plus/Minus Control

Control of sample's mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentazione
Data Sheet Data Sheet
Data Sheet

Vista
Vista
Salva
Salva

Choose more product:
Vista Vista SalvaSalva
Software Manual - CBCP 03
Software Manual - CBCP 03
Vista
Vista
Salva
Salva
(0.23 MB)
User Manual - WLY Multifunctional Scale
User Manual - WLY Multifunctional Scale
Vista
Vista
Salva
Salva
(1.63 MB)
Software Manual - Appendices 01
Software Manual - Appendices 01
Vista
Vista
Salva
Salva
(1.81 MB)
Start up Guide
Start up Guide
Vista
Vista
Salva
Salva
(1.92 MB)
Software Manual - PUE 7.1
Software Manual - PUE 7.1
Vista
Vista
Salva
Salva
(6.55 MB)
Conformity Declaration
Conformity Declaration
Vista
Vista
Salva
Salva
(0.04 MB)
Laboratory balance cleaning
Laboratory balance cleaning
Vista
Vista
Salva
Salva
(2.52 MB)
RTP Thermal Receipt Printer
RTP Thermal Receipt Printer
Vista
Vista
Salva
Salva
(1.64 MB)
THBR System 2.0
THBR System 2.0
Vista
Vista
Salva
Salva
(5.17 MB)
Laboratory Balances
Laboratory Balances
Vista
Vista
Salva
Salva
(1.68 MB)
Stainless Steel in RADWAG products. Standard and special applications
Stainless Steel in RADWAG products. Standard and special applications
Vista
Vista
Salva
Salva
(2.23 MB)
PUE 7.1 Terminal
PUE 7.1 Terminal
Vista
Vista
Salva
Salva
(2.33 MB)
Software
Drivers

LabVIEW (3.05 MB)

Accessori

Newsletter

Subscribe to the newsletter if you would like to receive RADWAG news.

View more
Radwag bilance e sistemi di pesatura
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 Radwag bilance e sistemi di pesatura. Diritti riservati

selezionare

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Français Français
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail
nome azienda:
Nome:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩