XA 21.4Y.M Microbalance

This image is for reference only.
CE
Informa about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
CE
Informa about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
CE
Informa about conformity of a product with European Union regulations that concern the product. Marking the product with CE sign makes the manufacturer responsible for the product to meet requirements of general safety regulations determined by CE marking directives.
Verification
The procedure within the scope of Legal Metrology. It is performed by regional Offices of Measures or authorized entities before the new product is introduced to the market. The procedure is performed on the basis of tests validating conformity of a product with the directives. For most measuring devices, including balances and scales, this procedure has been replaced with declaration of conformity.
2 years warranty
Request for quotation

Overview

4Y.M microbalances feature modern design that enables high accuracy and fast measurements.
They are equipped with reliable measuring system housed within a tight casing. With this feature, the balance provides accuracy and fast measurement for almost any laboratory conditions. The electronic part of the balance features modern hardware and software architecture. Integrated software, Windows Embedded Compact 7, Flash memory, Double Hardware System guarantee speed and reliability of collecting and processing information. 4Y.M series is equipped with 5.7" LCD colour touch screen which improves weighing instruments operation and presenting measurements results. Complex databases enable to register, print and export measurements. The weighing instrument system supports 13 languages. 4Y.M microbalance is an optimized modern tool equipped with an automatic levelling control system (LevelSENSING).

Customization option is based on individual operators’ profiles and permissions levels that limit the access to the weighing instrument's menu. Programmable proximity sensors offer wide range of possibilities: zeroing, taring, printing and more.
Numerous functions, such as differential weighing, enable multi-step mass control of the same sample subjected to different processes.
The software security system and the ability to document the process using printouts (standard/non-standard) ensures compliance of the weighing instruments with GLP/GMP systems in almost every area (pharmacy, petrochemistry, environment protection and many others). 
CAUTION:
In order to carry out the weighing process by means of microbalances and ultra-microbalances correctly, it is necessary to prepare the workstation and to operate the device as required.
Usage and installation guidelines are to be found in the following document: Installation and usage conditions for ultra-microbalances and microbalances.

Functions

Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Datasheet

Max capacity [Max]
21 g
Minimum load
0,1 mg
Readability [d]
1 µg
Tare range
-21 g
Repeatability
2 µg
Linearity
±9 µg
Eccentric load deviation
15 µg
Sensitivity temperature drift
1×10⁻⁶/°C×Rt 
Sensitivity stability
1×10⁻⁶/Year×Rt 
Minimum weight (USP)
4 mg
Minimum weight
0,4 mg
Weighing chamber dimensions
170×200×220 mm
Stabilization time
~ 3,5 s
Adjustment
internal 
Working temperature
+10÷+40 °C
Atmospheric humidity
40% ÷ 80% 
Power supply
13,5 ÷ 16 V DC 
Display
5,7'' (panel touchscreen) 
Interface
2×USB, 2×RS 232, Ethernet, Wireless Module, 4 Inputs, 4 Outputs (digital) 
Pan Size
ø 30 mm
Packaging size
720×385×485 mm
Net weight
9,8 kg
Gross weight
14,3 kg
Power consumption
700mA (wireless terminal - 1A) 

Documentation

Technical Documentation
Publications and teaching materials
☎ Call us now
✉ Get a quote

© 2018 RADWAG USA L.L.C.. All rights reserved.

All proprietor's rights do the materials placed in the server are in possession of RADWAG USA L.L.C. and are not to be copied, processed and utilized in commercial purpose unless agreed with RADWAG USA L.L.C. .

RADWAG USA L.L.C.
19599 NE 10th Ave., #E, North Miami Beach, FL, 33179 USA
tel.: 13056513522